Description
APC UPS Network Management Card 2 with PowerChute Network Shutdown AP9630
-
Remote monitoring and control of an individual UPS by connecting it directly to the network.
-
Includes: CD with software, User manual
AP9630 Features
UPS Network Management Card 2
Remote monitoring and control of an individual UPS by connecting it directly to the network.
Includes: CD with software, User manual
-
BACnet/IP Support
Supports reporting UPS information to Building Management Systems or other third party management systems via BACnet/IP (BTL certified) (Single Phase Smart-UPS and Symmetra only).
-
Command line interface
Offers simultaneous remote management access through Telnet and SSH
-
Compatible with SmartSlot enabled UPSs
Compatible with all SmartSlot UPSs
-
Device Encryption
Securely connect via HTTPS/SSL, SSH (up to 2048-bit encryption), SNMPv3
-
IPv6 Support
Capable of operating on a network using IPv6 protocol
-
Modbus TCP Support
Supports reporting UPS information to Building Management Systems or other third party management systems via Modbus TCP.
-
Multiple language support
Web browser interface available in English, French, Russian, Chinese, Japanese, Korean, German, Italian, Spanish, Portuguese
-
Multiple user access
Supports simultaneous web browser access for up to 8 users and network command line interface access for up to 3 users
-
Smart Battery Management Support
Detailed battery information including battery cartridge parameters provides early-warning fault analysis to simplify management of the entire battery system (SRT Smart-UPS only).
-
Standard UPS RFC 1628 MIB Compatible
Make UPS information available to your preferred network, server or enterprise management system by forwarding SNMP traps (events) using RFC 1628 MIB.
-
UPS Firmware Update
User friendly mechanism to remotely and seamlessly update UPS firmware via the web browser interface (SMX, SMT and SRT Smart-UPS only).
UPS Network Management Cards Features & Benefits
Manageability
Data logging
Identify problematic trends before they escalate or export the data log for analysis.
Scheduled shutdown and reboot
Customize shut down and reboot of connected equipment and UPSs.
Notification
Be notified of problems to ensure crucial situations are dealt with in a timely manner.
Integrates with StruxureWare Data Center Expert
An IT-ready, scalable access monitoring system that collects, organizes, and distributes critical alerts, surveillance video and key information, providing a unified view of complex physical infrastructure environments from anywhere on the network
Event logging
Pinpoint the timing and sequence of events leading up to an incident with the event log.
Enterprise management system compatible
Make device information available to your preferred enterprise management system by forwarding SNMP traps (events) across SNMPv1 and SNMPv3 using the PowerNet MIB
Marketing features
Remote device management
Enable management of your UPS by connecting it directly to the network.
Fault notification
Real-time event notification minimizes response times to critical physical infrastructure situations. Enables IT Administrators to reduce mean time to repair, improve efficiency, and maximize uptime.
Protection
Radius support
Use an existing radius server to securely authenticate, authorize, and account for your APC device.
Password security
User-selectable password with strong password rules and reset password mechanism.
Network Shutdown
Reliable network-based shutdown of multiple servers
Multi-tier user access
Supports up to four access levels - Administrator, Device User, Read-Only User and Network-only User - with user name and password requirements.
Total cost of Ownership
Browser Accessible
View the user interface with a browser. Provides quick access from anywhere on a secure network.
Flash upgradeable firmware
Install maintenance releases of firmware remotely using FTP.
Communications & Management
Authentication
Radius
Physical
Maximum Height
1.5inches (38MM, 3.8CM)
Maximum Width
4.76inches (121MM, 12.1CM)
Maximum Depth
4.49inches (114MM, 11.4CM)
Net Weight
0.18lbs. (0.08KG)
Shipping weight
0.75lbs. (0.34KG)
Shipping Height
2.01inches (51MM, 5.1CM)
Shipping Width
9.25inches (235MM, 23.5CM)
Shipping Depth
6.26inches (159MM, 15.9CM)
Color
Black
Environmental
Operating Temperature
32 - 113 °F (0 - 45 °C)
Operating Relative Humidity
0 - 95 %
Operating Elevation
0 - 10000ft (0 - 3048meters)
Storage Temperature
-5 - 45 °C
Storage Relative Humidity
0 - 95 %
Storage Elevation
0 - 50000ft (0 - 15240meters)
Conformance
Approvals
AS/NZS 3548 (C-Tick) class A, EN 55022 class A, EN 55024, FCC part 15 class A, GOST, ICES-003, VCCI class A
Standard warranty
2 years repair or replace
Sustainable Offer Status
RoHS
Compliant
PEP
Available in Documentation tab
EOLI
Available in Documentation tab
Documentation
Manuals and Warranties
UPS Network Management Cards : Installing Multiple Management Cards (Manual Addendum)
Installation; Integration with other Products
Security Handbook Network Enabled Devices AOS v6.9.X
Security Configuration
Security Handbook for APC Network Management Cards AOS v5.x.x
Security, Configuration
Network Management Card 2 for Symmetra® PX
AP9630 (CH) Network Management Card, AP9631 (CH) Network Management Card, AP9635 (CH) Network Management Card
UPS Network Management Card - Modbus Register Map for Symmetra PX 20-160 kW
This modbus register map is for devices with "sy3p" or "px2" version 6.5.0 and higher NMC2 firmware applications
Network Management Card for Galaxy 300 10-80 kVA Release Notes
Network Management Card for Galaxy 300 10-80 kVA Release Notes
Network Management Card for Galaxy 300 10-80 kVA Modbus Register Map
Modbus Register Map: Galaxy 300
Agency Approvals
Declaration of Conformity - Low Voltage Products with Microprocessor
Declaration of Conformity
EU Declaration of Conformity CE, AP9630, AP9631, AP9635
European CE Compliance
Li Coin Cell, Certification for SafeTransport, China, CR2032
Safe Transportation of Chemical Goods
EMC Compliance Certificate EU/EN/CE, US/FCC, Japan/VCCI for the AP9630 & AP9631
Regulatory Compliance
Environmental Profile
EoLi - UPS Network Management Cards
End of Life Instruction (EoLI) for the UPS Network Management Cards Product Range
ePEP - UPS Network Management Cards
Product Environmental Profile (ePEP) for the UPS Network Management Cards
Product Comparison Between AP9640, AP9641 and AP9643
Remotely manage your UPS on your existing network with Datacenter, Building Management or Industrial Automation Systems using the UPS Network Management Card 3. Remote management can save time and money with the ability to reboot hung devices restoring functionality without deploying personnel.
Features | Benefit |
AP9643 |
||
SNMP Management (v1/v2/v3) | Monitor and manage your UPS as one of your network devices over your preferred Enterprise Network Management System by forwarding SNMP traps (events) across SNMP (v1/v2/v3) using the PowerNet MIB. |
√ | √ | √ |
Data Event Logging | Identify problematic trends and take appropriate action before they escalate or export logs for analysis |
√ | √ | √ |
IPv6 Support | Ready to support the next generation of IP networking with the trending Internet of Things (IoT) and Industrial IoT. |
√ | √ | √ |
Smart Battery Management (SRT and SRTL Smart-UPS Only) |
Manage and maintain entire battery system with detailed battery information, even battery cartridge parameters, providing early fault warning. Helps you plan preventative battery maintenance. |
√ | √ | √ |
User-Friendly Firmware Upgrade Capability | Install maintenance releases off firmware remotely to your NMC or UPS* ensuring ongoing remote management of your UPS. *SMT, SMTL, SMX, SRT, SRTL models* |
√ | √ | √ |
BACnet/IP and Modbus TCP Support | Integrate your UPS to existing networks with 3rd party Building Management System and Industrial Automation Systems |
√ | √ | √ |
Two USB Ports | Support UPS NMC firmware upgrade | √ | √ | |
USB Wi-Fi Device Compatible | Providing secure wireless internet to your connected devices (UPS and Rack PDUS). Drives operational efficiency, reducing downstream costs and clutter from traditional cabling |
√ | √ | |
Temperature and (optional) Temperature & Humidity Monitoring AP9335T-included, AP9335TH-optional |
Monitor temperature or temperature and humidity and take appropriate action when needed to ensure best possible performance from your UPS |
√ | √ | |
Optional Dry Contact IO Accessory (AP9810) Support |
Monitor external triggers and initiate actions or external devices | √ | √ | |
Additional Protocol Interface (4-wire Modbus RTU) |
Supports device communication on a Modbus serial line using the RTU. This mode has greater character density. |
√ |
Which model of UPS Network Management Card is supported in my UPS?
Product Line
-
UPS Network Management Card 3 - AP9640, AP9641
- UPS Network Management Card 4 - AP9644
- UPS Network Management Card 2 - AP9630/30CH, AP9631/31CH, AP9635/35CH
- UPS Network Management Card 1 - AP9617, AP9618, AP9619
- UPS Web/SNMP Card - AP9606
Network Management Card Model(s) | UPS Model | Note(s) |
AP9640, AP9641
|
|
|
AP9644
|
|
*Includes built-in network management card. Notes:
|
AP9630/30CH, AP9631/31CH
|
|
|
AP9630/30CH, AP9631/31CH, AP9635/35CH
|
|
|
AP9635/35CH
|
|
|
AP9617, AP9618, AP9619
|
|
**Note: This add-on option is only able to monitor the UPS, and not any power distribution. The embedded NMC within the UPS must be used to monitor any power distribution. |
AP9606
|
|
Payment & Security
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
You may also like