Features
-
Adjustable voltage sensitivityProvides the ability to adapt the UPS for optimal performance in specific power environments or generator applications.
-
Adjustable voltage-transfer pointsMaximizes useful battery life by widening the input voltage window or tightening the output voltage regulation.
-
Audible alarmsProvides notification of changing utility power and UPS power conditions
-
Automatic restart of loads after UPS shutdownAutomatically starts up the connected equipment upon the return of utility power.
-
Automatic self-testPeriodic battery self-test ensures early detection of a battery that needs to be replaced.
-
Battery failure notificationProvides early-warning fault analysis on batteries enabling timely preventive maintenance
-
Boost and Trim Automatic Voltage Regulation (AVR)Eliminates voltage fluctuations as a source of AV signal degradation and component power-supply stress.
-
Cold-start capableProvides temporary battery power when the utility power is out.
-
Disconnected battery notificationWarns when a battery is not available to provide backup power.
-
Energy meterProvides actual kilowatt hours of usage for energy conscious users.
-
Frequency and voltage regulationGives higher application availability by correcting poor frequency and voltage conditions without using the battery.
-
Green modePatent-pending operating mode that bypasses unused electrical components in good power conditions to achieve very high operating efficiency without sacrificing any protection.
-
High online efficiencyReduces utlility costs, generates less heat.
-
Hot-swappable batteriesEnsures clean, uninterrupted power to protected equipment while batteries are being replaced
-
Intelligent battery managementMaximizes battery performance, life, and reliability through intelligent, precision charging.
-
Intuitive LCD interfaceProvides clear and accurate information in multiple languages with the ability to configure the UPS locally with easy to use navigation keys.
-
LED IndicatorsProvide easy-to-read status of the unit and utility power conditions.
-
Network manageableProvides proactive notifications of changing power or unit conditions and provides the user the ability to remotely control PMU functions.
-
Outlet group controlTurn on/off, reboot or shut down select outlet groups to save dispatching technicians to remote locations (for UPSs with switched outlet groups).
-
Predicitive failure notificationProvides early-warning fault analysis ensuring proactive component replacement.
-
Predictive replace battery dateDynamically provides the month and year when battery replacement is recommended to aide in long term maintenance planning.
-
Pure sine wave output on batterySimulates utility power to provide the highest degree of compatibility for active PFC (power factor corrected) servers and sensitive electronics.
-
Safety-agency approvedEnsures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.
-
Sequenced network shutdown and rebootCustomize network shutdown and reboot sequence of connected servers and UPSs.
-
Serial connectivityUse any Home Automation network to monitor and control the S20 through its RS-232 serial port. For information on how to communicate with the S20, see APC's Application Note #102. Crestron and AMX installers should visit their respective websites for information on how to integrate the S20 into those networks.
-
Single switched outlet groupSingle outlet group that may be controlled separately from the UPS for discrete reboot of hung devices, sequenced on/off and non-critical load shedding.
-
StruxureWare Data Center Expert compatibleEnables centralized management via StruxureWare Data Center Expert.
-
Temperature-compensated battery chargingProlongs battery life by regulating the charge voltage according to battery temperature.
-
USB connectivityProvides management of the UPS via a USB port (not available on all models).
-
User-replaceable batteriesIncreases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)
-
Wide input voltage rangeDesigned for harsh electrical environments to save battery life.
Smart-UPS Features & Benefits
Safety
-
Safety-agency approvedEnsures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.
Serviceability
-
Predictive failure notificationProvides early-warning fault analysis ensuring proactive component replacement.
-
Hot-swappable batteriesEnsures clean, uninterrupted power to protected equipment while batteries are being replaced
-
User-replaceable batteriesIncreases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)
-
Battery failure notificationProvides early-warning fault analysis on batteries enabling timely preventive maintenance
-
Resettable circuit breakersEnables a quick recovery from overload events.
Adaptability
-
Adjustable voltage-transfer pointsMaximizes useful battery life by widening the input voltage window or tightening the output voltage regulation.
-
Adjustable voltage sensitivityProvides the ability to adapt the UPS for optimal performance in specific power environments or generator applications.
Availability
-
Disconnected battery notificationWarns when a battery is not available to provide backup power.
-
Automatic self-testPeriodic battery self-test ensures early detection of a battery that needs to be replaced.
-
Boost and Trim Automatic Voltage Regulation (AVR)Gives higher application availability by correcting low and high voltage conditions without using the battery (not available on all models).
-
Power conditioningProtects connected loads from surges, spikes, lightning, and other power disturbances.
-
Intelligent battery managementMaximizes battery performance, life, and reliability through intelligent, precision charging.
-
Automatic restart of loads after UPS shutdownAutomatically starts up the connected equipment upon the return of utility power.
-
Temperature-compensated battery chargingProlongs battery life by regulating the charge voltage according to battery temperature.
Manageability
-
Network manageableProvides remote power management of the UPS over the network.
-
Disconnected battery notificationWarns when a battery is not available to provide backup power.
-
USB connectivityProvides management of the UPS via a USB port (not available on all models).
-
Serial connectivityProvides management of the UPS via a serial port.
-
LED status indicatorsQuickly understand unit and power status with visual indicators.
-
Audible alarmsActively let you know if the unit is on battery, if the battery is low or if there is an overload condition.
Technical Specification
Output
-
Output power capacity : 2.7 KWatts / 3.0 kVA
-
Max Configurable Power (Watts) : 2.7 KWatts / 3.0 kVA
-
Nominal Output Voltage : 230V
-
Output Voltage Note : Configurable for 220 : 230 or 240
nominal output voltage
-
Output Frequency (sync to mains) : 47 - 53 Hz for 50 Hz
nominal, 57 - 63 Hz for 60 Hz nominal
-
Other Output Voltages : 220, 240
-
Topology : Line Interactive
-
Waveform type : Sine wave
-
Output Connections(3) IEC Jumpers (Battery Backup)(1) IEC 320 C19 (Battery Backup)(8) IEC 320 C13 (Battery Backup)
-
Transfer Time : 4ms typical : 8ms maximum
Input
-
Nominal Input Voltage : 230V
-
Input frequency : 50/60 Hz +/- 3 Hz (auto sensing)
-
Input Connections : British BS1363A, IEC-320 C20, Schuko CEE 7/EU1-16P
-
Cord Length : 2meters
-
Input voltage range for main operations : 160 - 286V
-
Input voltage adjustable range for mains operation : 151 - 302V
-
Number of Power Cords : 1
-
Other Input Voltages : 220, 240
Batteries & Runtime
-
Battery type : Maintenance-free sealed Lead-Acid battery with suspended electrolyte : leakproof
-
Typical recharge time : 3hour(s)
-
Replacement Battery : RBC43
-
Expected Battery Life (years) : 3 - 5
-
RBC Quantity : 1
-
Runtime
-
Efficiency
Communications & Management
-
Interface Port(s) : USB
-
Control panel : LED status display with On Line : On Battery : Replace Battery and Overload indicators, Multi-function LCD status and control console
-
Audible Alarm : Alarm when on battery : distinctive low battery alarm : configurable delays
-
Available SmartSlot™ Interface Quantity : 1
Surge Protection and Filtering
-
Surge energy rating : 320Joules
Physical
-
Maximum Height : 86mm , 8.6CM
-
Maximum Width : 480mm , 48.0CM
-
Maximum Depth : 683mm , 68.3CM
-
Rack Height : 2U
-
Net Weight : 44.28KG
-
Shipping weight : 51.7KG
-
Shipping Height : 254mm , 25.4CM
-
Shipping Width : 600mm , 60.0CM
-
Shipping Depth : 980mm , 98.0CM
-
Units per Pallet : 8.0